Field Probe
Model WP Series Field Probe
Thương hiệu VIAM VINA
Giá Liên hệ Hotline để có giá tốt nhất

HOT LINE

TEL: +84 222 3895 596
MOBILE: +84 969 095 867

EMAIL

sales@viamvina.com.vn

EMF safety field probe selection chart DC 180207


WP50 Field Probe

10 Hz - 3 kHz
E & H field
Broadband

 

MAIN APPLICATIONS

  • Energy: IEC/EN 62110
  • Induction heating: EN 50519
  • Electric arc or induction smelting
  • Workplace assessment: EN 50499
  • Human exposure assessment: EN 50413
  • Other low frequency applications

In accordance with IEC/EN 61786-1.

DATA SHEET  CONTACT US

WP50

Compatible with:

smp2
SMP2

monitem
MonitEM


WP400 Field Probe

1 Hz - 400 kHz
E & H field
Selective & Broadband

 

MAIN APPLICATIONS

  • Energy: IEC/EN 62110
  • Railway: EN 50500
  • Welding: EN 50505
  • Induction heating (LF): EN 50519
  • Electric arc or induction smelting
  • Household appliances: IEC/EN 62233, EN 50366
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Medical: IEC 60601
  • Research/Labs
  • Electronic/electrical equipment: IEC/EN 62311
  • Defence (LF) 
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413

In accordance with IEC/EN 61786-1.

DATA SHEET  CONTACT US

WP400

Compatible with:

smp2
SMP2


WP400-3 Field Probe

1 Hz - 400 kHz
E & H field
Selective & Broadband

 

MAIN APPLICATIONS

  • Assessment of:
    • Welding equipment: IEC/EN 62822, EN 50505
    • Household appliances: IEC/EN 62233, EN 50366
    • Other electronic/electrical equipment: IEC/EN 62311
  • Research/Labs 
  • Other application where small size and spatial resolution is important

In accordance with IEC/EN 61786-1.

DATA SHEET  CONTACT US

WP400-3

Compatible with:

smp2
SMP2


WPF3 Field Probe

100 kHz - 3 GHz
E field
Broadband

 

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Plastic welding
  • Semiconductor production
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying

DATA SHEET  CONTACT US

WPF3

Compatible with:

emf meter Smp2
SMP2

Area monitoring Monitem
MonitEM

Area monitoring Monitem-lab
MonitEM-Lab


WPF6 Field Probe

100 kHz - 6 GHz
E field
Broadband

 

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401, EN 50492
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Plastic welding
  • Semiconductor production
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying

DATA SHEET  CONTACT US

WPF6

Compatible with:

emf meter Smp2
SMP2

Area monitoring Monitem
MonitEM

Area monitoring Monitem-lab
MonitEM-Lab


WPF8 Field Probe

100 kHz - 8 GHz
E field
Broadband

 

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401, EN 50492
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Plastic welding
  • Semiconductor production
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying

DATA SHEET  CONTACT US

WPF8

Compatible with:

emf meter Smp2
SMP2

Area monitoring Monitem
MonitEM

Area monitoring Monitem-lab
MonitEM-Lab


WPF18 Field Probe

300 kHz - 18 GHz
E field
Broadband

 

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Plastic welding
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
  • Radar
  • Defence (HF)

DATA SHEET  CONTACT US

WPF18

Compatible with:

emf meter Smp2
SMP2

Area monitoring Monitem
MonitEM

Area monitoring Monitem-lab
MonitEM-Lab


WPF40 Field Probe

20 MHz - 40 GHz
E field
Broadband

 

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
    • Satellite installations
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
  • Detection of leaks
  • Radar
  • Defence (HF)

DATA SHEET  CONTACT US

WPF40

Compatible with:

emf meter Smp2
SMP2

Area monitoring Monitem
MonitEM

Area monitoring Monitem-lab
MonitEM-Lab


WPH60 Field Probe

300 kHz - 60 MHz
H field
Broadband

 

MAIN APPLICATIONS

  • Broadcasting: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs

DATA SHEET  CONTACT US

WPH60

Compatible with:

smp2
SMP2

monitem
MonitEM


WPH1000 Field Probe

30 MHz - 1000 MHz
H field
Broadband

 

MAIN APPLICATIONS

  • Broadcasting: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Defence

DATA SHEET  CONTACT US

WPH1000

Compatible with:

emf meter Smp2
SMP2

Area monitoring Monitem
MonitEM

Area monitoring Monitem-lab
MonitEM-Lab


WPH-DC Probe

DC - 40 kHz
H Field
Selective & Broadband

 

APPLICATIONS

  • Medical (MRI: Magnetic Resonance Imaging): IEC 60601-2-33
  • Railway (DC Motors): EN 50500
  • Automotive (Electrical vehicles)
  • Chemical Industry (Electrolysis)
  • Strong Permanent Magnets (Heavy duty magnet lifters)
  • Energy (DC generators)
  • Metrology (Earth static field)



DATA SHEET  CONTACT US

WPH-DC

Compatible with:

smp2
SMP2


WPT Field Probe

Bands: 700-900, 1800-1900, 2100 and 2600
E field
Selective broadband

 

MAIN APPLICATIONS

  • Assessment of mobile telephony base stations



DATA SHEET  CONTACT US

WPT

Compatible with:

smp2
SMP2

monitem
MonitEM


WP-WiFi Field Probe

Band: 2400-2500
E field
Selective broadband

 

MAIN APPLICATIONS

  • Assessment of WiFi transmitters


DATA SHEET  CONTACT US
WPTWIFI

Compatible with:

smp2
SMP2

monitem
MonitEM