Schwarzbeck MagTest System
Schwarzbeck MagTest System
Schwarzbeck MagTest System
MagTest System
System to test the immunity against magnetic fields acc.
MIL-461 E, ISO 11452-8, EN 61000-4-8, SAE J551-17 etc.
The system components will be individually configured for your requirements.
LFPA 9733 B Power Amplifier
The LFPA 9733 B is a multi-purpose power amplifier
and can be used within the frequency range from
5 Hz to 1 MHz.
Typical applications are magnetic immunity testing
according to automotive standards or MIL-461 E or F.
Frequency range (nominal): 5 Hz – 1 MHz
Gain: 26 dB ±3 dB
Max. output voltage: 60 Vpeak
Max. output current: 40 Apeak
NFCN 9734 Compensation Network
The primary function of the compensation network NFCN 9734 is to provide a serial compensation of the inductance of Helmholtz coils (e.g. the HHS 5206-16). Thus the currents needed to produce the desired field strength can be achieved using relatively low voltages.
Max continuous current: | up to 32 Arms | |
Dimensions: | 447 mm x 470 mm x 191 mm | |
Capacitance range: | 270 pF – 480 µF | |
Frequency range: | DC – 200 kHz | |
Integrated shunt: | 0.5 Ohm / 400 W | |
Weight: | 17.5 kg |
SHUNT 9571
Low inductive precision high power shunt
1 x 0.25 Ohm / 800 W
1 x 1 Ohm / 800 W
2 x 0.5 Ohm / 400 W
respectively for best load matching
at lower frequency end
cooling fans
HS 5136 – Hall-Sensor
Nominal frequency range: | DC – 1 kHz | |
Nominal measuring range: | 0 – 7000 A/m | |
Extended measuring range: | 0 – 9000 A/m | |
Nominal conversion factor: | 1 (A/m)/mV | |
Load impedance: | >2 kΩ | |
Non-linearity.: | 0.8 % | |
Power supply: | 12 VDC ±3 % / 250 mA | |
Housing: | Aluminium | |
Dimensions: | ca. 470 x 42 x 28 mm | |
Mounting: | D = 22 mm Tube, L = 120 mm | |
Weight: | 330 g | |
Connector: | BNC-female |