Powerline 100 Amp CDN for Two Conductors Com-Power CDN-M2100
I Introducing the CDN-M2100
CDN-M2100 is a Coupled Decoupling Network with two-conductor power cable. This M series CDN has a current rating of 100 Amps. This CDN has a frequency range of 150 kHz – 230 MHz. Noise signals are coupled to each conductor in the supply line according to EN 61000-4-6 and are recommended for all mains connections.
II Specifications of CDN-M2100:
Frequency Range: 150 kHz to 230 MHz
Current Ratings of 25, 50 and 100 Amps
Single-Line (M1), Two-Line (M2), Three-Line (M3), Four-Line (M4) and Five-Line (M5) Models
Fully Compliant with CISPR 16-1-2 and IEC 61000-4-6
Three-Year Warranty
Product Name: Coupling Decoupling Network (CDN)
Compliant Test Standards: IEC / EN 61000-4-6
Application: Two conductor power cable
Frequency Range: 150 kHz to 230 MHz
RF Input Voltage: 40 V (Max)
RF Input Connector: 50 Ω BNC (Female)
Voltage Rating: 250 V AC / 350 V DC (Line to Ground)
Current Rating: 25 Amps AC / 17 Amps DC (Max)
AE and EUT Connections: 4 mm shrouded banana sockets
Common Mode Impedance
150 kHz – 26 MHz: 150Ω ± 20Ω
26 MHz – 80 MHz: 150Ω + 60Ω / – 45Ω
80MHz – 230MHz: 150Ω + 60Ω / – 60Ω
Voltage Division Factor: 9.5 dB +4 / -1
Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE)
Dimensions: 6 x 6 x 13 inches or 15.2 x 15.2 x 33 cm
Weight: 5 lbs. or 2.3 kg
Accessories Available from Com-Power for setting test levels and running the test:
ADA-M225E shorting adapters
ADA-515-2 150 Ω to 50 Ω adapters
TEP-050 50 Ω Terminator
ATTN-6-100W Power Attenuator
DCU-300-100W Directional Coupler
ASC series Power Amplifiers
III Chart of CDN-M2100: