Com-Power AL-130R Active Loop Antenna for EMC Test
I Introducing Com-Power AL-130R:
Model AL-130R complies with CISPR 16-1-4. It is ideal for emissions measurements required by various EMC standards such as FCC 18, CISPR 11, CISPR 13, CISPR 14, CISPR 32 and many others. The integrated low-noise preamplifier increases overall measurement sensitivity as well as overall signal-to-noise ratio. According to ANSI C63.4-2014, active loop antennas may be used for compliance testing in unshielded environments ONLY if the saturation indicator is continuously monitored during testing. Com-Power’s Remote Antenna Interface (RAI-100) is useful for this application. This is a compact controller that can be used to turn on/off the RF measurement circuit and monitor saturation and low battery levels remotely via a fiber optic cable up to 30 m in length.
II Com-Power AL-130R Specifications:
Frequency Range: 9 kHz – 30 MHz
Built-in, Battery Operated Preamplifier
Fiber Optic Remote Monitor/Control option
Electric or Magnetic Field Measurements
Individual Calibration per IEEE 291 Included
Three-year Standard Warranty
Product Name: Active Loop Antenna
Frequency Range: 9 kHz to 30 MHz
Loop Size: 19″ x 19″ (0.5 m x 0.5 m)
Nominal Impedance: 50 Ω (output port)
Battery Type: 6 VDC NimH (rechargeable)
Average Battery Life: 10 – 12 Hours
E-Field Antenna Factors: 13.4 to 16.4 (average: 14-9) [dB(m-1)]
Saturation Level: >1 V/m / >120dBμV/m (>2.65 mA/m) / >68.5 dBμA/m
Antenna Factor Variation: ±1.5 dB
RF Connector: BNC-type (female)
Specifications: ANSI C63.4, CISPR, EN, ETSI, etc.
Dimensions (H x W x D): 20.1″ x 19.7″ x 10.6″ [51 x 50 x 27 cm]
Weight: 5.5 lbs. [2.5kg]
III Chart of Com-Power AL-130R :