Com-Power LISN LIN-120C 20 Amps for CISPR 16 & ANSI C63.4
I Introducing LISN LIN-120C:
LISN 150 kHz to 30 MHz, 20 Amp The LIN-120C Line Impedance Stabilization Network (LISN) provides the measurement platform necessary to perform emissions compliance testing conducted on power lines as required by the Most standards worldwide are for commercial products. The LIN-120C complies with both CISPR 16-1-2 and ANSI C63.4.LISN provides stable defined impedance and isolates the EUT from power source influences, thereby providing accurate and reproducible results. repeat. The LIN-120C consists of a single pair of conductor networks, placed together, installed in series with each current-carrying conductor in a single-phase, two-phase or DC electrical system. A second pair of LIN-120Cs can be used to provide a 3-phase power system (Wye or Delta configuration).
II Technical specifications of LIN-120C
Product Name: Line Impedance Stabilization Network (LISN)
Specification: CISPR 16-1-2 / ANSI C63.4
Application: Power Line conducted emission tests
Frequency Range: 150KHz – 30 MHz
RF Connector: 50 Ohms N-type (female)
Current Rating: 20 Amperes AC, 14 Amperes DC
Voltage Rating: 270 VAC (Line to Ground), 380 VDC
Inductors: 50 microhenry (air-core)
Mains & EUT Connections: IEC 60320, C-20 @Mains and Universal multi-configuration @ EUT
Dimensions (each network): 14 x 13 x 6.5 inches / 35.5 x 33 x 16.5 cm
Weight (each network): 10.5 lbs / 4.76 kg
Insertion Loss: <0.5 dB (150 kHz – 30 MHz)
Isolation: > 40 dB (150 kHz – 30 MHz)