CDN for One Balanced Unscreened Pair CDN-T2E
I Introducing CDN-T2E:
CDN-T2E is one of the Coupler/Decoupler Networks for testing products that use a balanced, unscreened pair for communication, such as Ethernet for conductive immunity according to IEC/EN 61000- 4-6. It has an RJ11 connector for both EUT and AE connections. The CDN-T2E can handle current up to 2 Amps. The RF noise signal coupling port is female BNC. It can handle RF input voltage up to 40V. The underside of the CDN is unpainted for easy and effective grounding. All Com-Power CDNs are individually calibrated. Com-Power CDN-T2E is fully compliant with the requirements in IEC 61000-4-6 and CISPR 16-1-2. All Com-Power CDNs can be purchased separately or as part of the CIS Series Conducted Immunity Test System (a pre-packaged solution that includes the ACS Series power amplifier and all accessories). to sue).
II CDN-T2E technical specifications:
Product Name: Coupling Decoupling Network (CDN)
Compliant Test Standards: IEC / EN 61000-4-6
Application: One unscreened, balanced pair
Frequency Range: 150 kHz to 230 MHz
RF Input Voltage: 40 V (Max)
RF Input Connector: 50 Ω BNC (Female)
Voltage Rating: 124 V AC / 125 V DC (Line to Ground)
Current Rating: 2 Amps (Max)
AE and EUT Connections: RJ 11
Common Mode Impedance:
150 kHz – 26 MHz: 150Ω ± 20Ω
26 MHz – 80 MHz: 150Ω + 60Ω / – 45Ω
80MHz – 230MHz: 150Ω + 60Ω / – 60Ω
Voltage Division Factor: 9.5 dB +4 / -1
Decoupling of Common Mode Disturbance:
150 KHz ≥ 45dB (RF/AE)
500 KHz ≥ 50dB (RF/AE)
230 MHz ≥ 50dB (RF/AE)
Dimensions: 8.5 x 4.5 x 3.5 inches or 21.5 x 11.4 x 8.8 cm
Weight: 5 lbs. or 2.3 kg
Accessories Available from Com-Power for setting test levels and running the test:
ADA-T2 shorting adapters
ADA-515-2 150 Ω to 50 Ω adapters
TEP-050 50 Ω Terminator
ATTN-6-100W Power Attenuator
DCU-300-100W Directional Coupler
ASC series Power Amplifiers